在线客服
✈️
FREE SHIPPING on Orders Over US$77
Go Shopping
FREE SHIPPING on Orders Over US$77
Sold worldwide
Estimate delivery times: 12-26 days (Int'l), 6-10 days (US).
Return within 30 days. Duties & taxes are non-refundable.

OM4 MPO Fiber,Multimode fiber(OM4),Type B,Cabo MPO OM4 8 Jumper PC (Female) to Cabo MPO OM4 8 Jumper PC (Female),OFNP-Plenum,1.5m (4.92ft)

SKU: MPO-8F(OM4)-PC-Female-TB-1.5m (4.92ft)

¥ 41.70

库存 99 件

  • MPO Connector with Optimal 0.35dB Low IL
  • Bend Insensitive Fiber with 7.5mm Min. Bend Radius
  • Mini Fiber Optic Cable OM4
  • Color-Coded Connector Boots for Easy Identification
  • Typically Used for Patching Within a Cabinet
  • Adopt high-quality environmentally friendly flame-retardant PVC outer sheath(OFNP Plenum), low-carbon and safe, safe to use
  • Typically Used for Patching Within a Cabinet
  • All materials have passed REACH/ROHS environmental protection requirements and are of export quality
  • Compliant to IEC 61754-7, ANSI/TIA-604-5 and ANSI/TIA-568.3-D
描述

MPO OM4 Cable Types

The MPO jumper cable offers an affordable solution compared to the effort-intensive process of field termination. It is optimized for dense fiber patching in data centers, where conserving space and reducing cable complexity are key priorities. In addition, the bend-insensitive fiber technology supports dependable, high-level performance, even when cables are routed through constrained or sharply bent areas.

 

MPO Om4 Advantage Specifications

Connector A:MPO (Pinless)
Connector B:MPO (Pinless)
Polish Type:PC to PC
Fiber Mode:OM4 50/125μm
Wavelength:850/1300nm
Fiber Count:8 Fibers
Polarity:Type B
Cable Outside Diameter (OD):3.0mm
Cable Jacket:Plenum (OFNP)
Min. Bend Radius (Optical Fiber):7.5mm
Min. Bend Radius (Fiber Cable):20/10D (Dynamic/Static)
Connector Durability:500 times
Tensile Strength:90/180N (Long/Short Term)
Insertion Loss:0.35dB Max
Return Loss:≥25dB
Operating Temperature:-10 to 60°C (14 to 140℉)
Storage Temperature:-10 to 70°C (14 to 158℉)

 

MPO OM4 Patch Cord Polarity

The MPO 8-fiber Type B female connector is a high-density fiber optic interface widely used in parallel optics and structured cabling systems. It follows the Type B polarity (reversed configuration), meaning the fiber positions are mirrored from one end to the other.

For example:

  • Fiber 1 → Fiber 12
  • Fiber 2 → Fiber 11
  • Fiber 3 → Fiber 10
  • Fiber 4 → Fiber 9
  • Fiber 9 → Fiber 4
  • Fiber 10 → Fiber 3
  • Fiber 11 → Fiber 2
  • Fiber 12 → Fiber 1

This reversed mapping ensures that transmit (Tx) fibers on one end connect correctly to receive (Rx) fibers on the opposite end, which is essential for high-speed parallel transmission.

As a female connector, it does not include guide pins and is designed to mate with a male MPO connector (with pins), ensuring precise alignment and stable optical performance.

OM4 MPO Fiber Key Features:

Connector type: MPO 8-fiber female (without pins)
Fiber count: 8 fibers in a single-row MT ferrule
Polarity standard: Type B (reversed / flipped mapping)
Ferrule design: High-precision MT ferrule for accurate fiber alignment
Cable jacket options: OFNR, OFNP, or LSZH, with standard color coding (yellow for OS2, aqua/violet for OM3/OM4, lime green for OM5)

mtp cable types,cable mpo-mtp,mtp fiber meaning,mtp fiber cables,mtp fiber optics,mtp cable meaning,mtp patch cable,mtp to lc breakout cable,mtp fiber

mpo cable meaning,mpo cable tester,mpo cable polarity,mpo cable connector,mpo cable cleaner,mpo cable type a b c,mpo cable full form,mpo cable

 

Cabo MPO OM4 Advantage

  • Correct Tx/Rx alignment: Reversed polarity ensures proper signal transmission
  • High-density design: 8 fibers in one connector reduce cable bulk and save space
  • Reliable mating: Female connector pairs with male (pinned) connector for precise alignment
  • Scalable solution: Supports migration to higher-speed networks such as 40G and 100G

 

OM4 MPO Cable SPIN-LEAF connection method

mtp patch cable,mtp fiber patch cable,mtp mpo fiber patch cable,mtp mpo patch cable,mtp/mpo cable,mtp patch cord,mtp patch cords,mtp jumper cable

OM4 MPO Cable Application

High-speed interconnection in data centers

It is used for direct connection of 40G/100G optical modules, supports 400G high-speed transmission, and can improve wiring density and transmission efficiency. For example, 400G QSFP-DD DR4 optical modules can be directly connected through MPO/MTP-8 multimode fiber jumpers. ‌

High-density wiring scenarios

In the backbone wiring of data centers, MTP/MPO trunk fiber jumpers are used in conjunction with adapter modules to achieve interconnection and cross-connection between devices, saving 45% of wiring space. Branch jumpers are used to connect devices with different rates (such as 10G and 40/100G devices). ‌

100G/400G transmission expansion

Supports branch connection of 100G QSFP28 optical modules to 4 25G SFP28 optical modules, or interconnection of 100G CFP optical modules to another CFP. ‌

Fiber-to-Building Applications

It is used for fiber-to-the-building (FTTB) wiring to meet the needs of high-density fiber access.

mtp cable types,cable mpo-mtp,mtp fiber meaning,mtp fiber cables,mtp fiber optics,mtp cable meaning,mtp patch cable,mtp to lc breakout cable,mtp fiber

 

OM4 MPO Test Series

OM4 MPO MTP Polarity Test Process

‌End face cleaning: Use special equipment to remove end face contaminants to avoid affecting the test accuracy. ‌
Morphology detection: Analyze the end face microstructure through 3D imaging technology to detect surface roughness, scratches and other defects. ‌
Insertion loss test: Measure the contact loss between the fiber end face and the connector ferrule to evaluate the signal transmission quality. ‌
Polarity verification: Confirm the correspondence between the number of fiber cores and the connector guide hole to prevent communication failure caused by wrong connection. ‌

Fibra MPO OM4 Test Key Indicators

Cleaning efficiency: It must reach more than 98% to ensure that there are no residual stains on the end face. ‌
Detection accuracy: The resolution of 3D morphology detection must be less than 1.5μ, and the insertion loss error must be controlled within 0.3dB. ‌
Test time: It takes about 10 seconds to detect a single fiber core of a 12-core MPO jumper, and the overall test takes about 2 minutes.

OM4 MPOw Test Common Problems

Pollution sensitivity: Tiny particles on the end face will cause increased loss, and non-contact cleaning methods are required to protect the end face. ‌ ‌

mpo fiber patch cable,mpo 12 patch cable,mpo patch cable,mpo to lc patch cable,mpo patch cord,ethernet mpo patch cable,mpo jumper cable,mpo+

其他信息
length

1.5m (4.92ft)

Fiber Type

Multimode fiber(OM4)

MPO MTP Connector

MPO-PC (Female)-PC (Female)

MPO MTP Polarity Type

Type B

Fiber Number Of Cores

8 Cores Fiber

用户评价 (0)
评级

0.0

0 产品评分
5
0
4
0
3
0
2
0
1
0

评论此产品

与其他客户分享您的想法

撰写评论

评论

目前还没有评价

OM4 MPO Fiber,Multimode fiber(OM4),Type B,Cabo MPO OM4 8 Jumper PC (Female) to Cabo MPO OM4 8 Jumper PC (Female),OFNP-Plenum,1.5m (4.92ft) ¥ 41.70
主页 商店 大车 2 心愿单 帐户
购物车 (0)

购物车为空 购物车里没有产品。

主要菜单
您好, 登录

按类别购物 查看所有